Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Oral Implantol (Berl) ; 16(1): 43-51, 2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36861680

RESUMO

PURPOSE: To evaluate the impact of immediate and delayed zirconia implant placement on crestal bone loss and the clinical outcomes achieved with this approach 1 year after prosthetic loading. Further objectives were to evaluate the influence of age, sex, smoking, implant dimensions, platelet-rich fibrin application and location of the implants in the jawbone on the crestal bone level. MATERIALS AND METHODS: Clinical and radiographic analysis were performed to evaluate the success rates for both groups. The data were analysed statistically through a linear regression analysis. RESULTS: No significant difference was found between immediate and delayed implant placement concerning the amount of crestal bone loss. Sex, age, bone augmentation, diabetes and prosthetic complications did not have a statistically significant influence; only smoking had a negative and statistically significant influence on crestal bone loss (P < 0.05). CONCLUSIONS: Immediate or delayed placement of one-piece zirconia implants may be a good alternative to the use of titanium implants concerning success and survival.


Assuntos
Doenças Ósseas Metabólicas , Implantes Dentários , Humanos , Estudos Retrospectivos , Implantes Dentários/efeitos adversos , Fumar
2.
J Oral Maxillofac Surg ; 81(3): 308-317, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36442535

RESUMO

PURPOSE: Titanium dioxide (TiO2) particles detached from titanium dental implants by tribocorrosion can be phagocytosed by macrophages, releasing various proinflammatory cytokines at the implant sites that may trigger peri-implantitis. The study objective was to measure the association between peri-implantitis and the presence of non-allergy-related proinflammatory cytokines associated with TiO2 particles. METHODS: The investigators implemented a retrospective cross-sectional study and enrolled a sample of 60 subjects from a dental practice. Subjects were excluded if the plaque index was grade 3 (Silness and Löe). The predictor variable was a positive or negative TiO2 stimulation test, an in vitro macrophage proinflammatory response test. The outcome variable was peri-implantitis status defined as present or absent. Three groups were considered: control group with 20 patients without dental implants (group 1), 2 groups of patients with titanium dental implants, one without peri-implantitis (group 2), and the other with peri-implantitis (group 3) (n = 20 each). For patients with implants, depth of the gingival pockets of the implants were measured, and existing bleeding and suppuration were determined to assess peri-implantitis. Radiographs were taken if one or more factors applied to confirm the diagnosis of peri-implantitis. Further covariates were age, sex, duration of implant wear, and number of implants which were analyzed descriptively. Inferential analyses were undertaken using χ2 test, Kruskal-Wallis-, Wilcoxon-two-sample tests, and logistic regressions. RESULTS: The sample was composed of 35 female and 25 male patients with a mean age of 54.2 years (standard deviation = 14.76). The overall TiO2 stimulation test positivity frequency was 28.3% and were 30.0%, 5.0%, and 50.0% in the control, implants without peri-implantitis, and implants with peri-implantitis groups. No statistically significant differences could be seen in the frequencies of the TiO2 stimulation test results between control group and combined groups 2 and 3 (P-value = .84). The risk for positive TiO2 patients with a titanium implant of developing peri-implantitis was statistically significant and higher compared to negative TiO2 patients (odds ratio, 19.0 with 95% confidence interval [2.12,170.38]; P-value< .01). CONCLUSIONS: The data in this study showed a statistically significant relationship between a positive TiO2 stimulation test and peri-implantitis. Further studies with larger numbers of subjects are recommended to confirm this result.


Assuntos
Implantes Dentários , Peri-Implantite , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Peri-Implantite/induzido quimicamente , Titânio , Implantes Dentários/efeitos adversos , Citocinas , Estudos Retrospectivos , Estudos Transversais , Macrófagos
3.
Artigo em Inglês | MEDLINE | ID: mdl-35909817

RESUMO

Biomaterials of natural origin have recently gained increasing attention in the field of dental implantology. The requirements for such materials, however, are very high. In addition to high clinical efficiency in tissue regeneration, wound healing should be demonstrably positively influenced. The translational division for regenerative orofacial medicine of the Clinic and Polyclinic for Oral and Maxillofacial Surgery of the University Medical Center Hamburg-Eppendorf (UKE) is examining this research topic by investigating which innovative treatment methods for the reconstruction of bone defects or for augmentative procedures can be applied in the future or are already being applied in the field of oral and maxillofacial surgery.

4.
BMC Oral Health ; 22(1): 198, 2022 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-35606734

RESUMO

BACKGROUND: There is limited evidence for the use of zirconium dioxide implants in immediate implant placement as well as for related immediate loading protocols. The aim of this retrospective study was to investigate the survival rate, success and patient satisfaction of immediately placed zirconia implants compared to delayed placed implants. METHODS: The study included 58 partially edentulous patients who were treated between 2013 and 2015 with immediate and delayed transgingival healing zirconium dioxide implants (SDS, Kreuzlingen/ Switzerland). In addition to survival and success rate, marginal bone loss was assessed using radiographs and soft tissue was evaluated using Pink Esthetic Score. Oral health-related quality of life was investigated prospectively using a modified OHIP questionnaire. RESULTS: The cumulative survival rate of all implants included was 92% with 88% classified as full success. No significant difference was found between the bone levels of immediately and delayed placed and immediately and delayed loaded implants. The mean Pink Esthetic Score after final prosthetic rehabilitation was 12.2/14 points indicating excellent esthetic clinical results. Analysis of the OHIP questionnaire showed a mean value of 0.54/100 points reflecting a high patient satisfaction. CONCLUSIONS: Immediate and delayed placed as well as loaded zirconium dioxide implants showed excellent results regarding implant success and survival in this study. Zirconium dioxide implants may ensure excellent esthetic results and high patient satisfaction.


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Implantação Dentária Endóssea/métodos , Prótese Dentária Fixada por Implante , Humanos , Carga Imediata em Implante Dentário/efeitos adversos , Satisfação do Paciente , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento , Zircônio
5.
Materials (Basel) ; 15(2)2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35057216

RESUMO

The influence of UV light and non-thermal plasma on the osseointegration of yttria-stabilized zirconia implants (Y-TZP) comparing the two methods is unclear. The aim of this study was to show the influence of these methods on the osseointegration of dental zirconia implants in an animal model. A total of 54 implants were either untreated, treated with UV light (UV), or non-thermal oxygen plasma for 12 min and inserted into the parietal bones of six domestic pigs. The animals were sacrificed after a healing interval of two, four, and nine weeks. The degree of osseointegration was determined using histomorphometric determination of bone-to-implant contact values (BIC) and the bone-to-implant contact values within the retentive parts of the implants (BAFO). BIC values decreased in all groups after four weeks of healing and re-increased after nine weeks in all groups. BAFO increased significantly over time in all groups. However, there were no statistically significant differences in BIC and BAFO values between the control group and the test groups and over time. Clinical studies may follow to confirm the influence of cold plasma and UV light on the healing and survival of zirconia implants.

6.
Int J Mol Sci ; 22(2)2021 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-33477311

RESUMO

Encouraging clinical results were reported on a novel cone-in-cone coupling for the fixation of dental implant-supported crowns (Acuris, Dentsply Sirona Implants, Mölndal, Sweden). However, the presence or absence of a microgap and a potential bacterial leakage at the conometric joint has not yet been investigated. A misfit and a resulting gap between the conometric components could potentially serve as a bacterial reservoir that promotes plaque formation, which in turn may lead to inflammation of the peri-implant tissues. Thus, a two-fold study set-up was designed in order to evaluate the bidirectional translocation of bacteria along conometrically seated single crowns. On conometric abutments filled with a culture suspension of anaerobic bacteria, the corresponding titanium nitride-coated (TiN) caps were fixed by friction. Each system was sterilized and immersed in culture medium to provide an optimal environment for microbial growth. Positive and negative controls were prepared. Specimens were stored in an anaerobic workstation, and total and viable bacterial counts were determined. Every 48 h, samples were taken from the reaction tubes to inoculate blood agar plates and to isolate bacterial DNA for quantification using qrt-PCR. In addition, one Acuris test system was subjected to scanning electron microscopy (SEM) to evaluate the precision of fit of the conometric coupling and marginal crown opening. Throughout the observational period of one week, blood agar plates of the specimens showed no viable bacterial growth. qrt-PCR, likewise, yielded a result approaching zero with an amount of about 0.53 × 10-4 µg/mL DNA. While the luting gap/marginal opening between the TiN-cap and the ceramic crown was within the clinically acceptable range, the SEM analysis failed to identify a measurable microgap at the cone-in-cone junction. Within the limits of the in-vitro study it can be concluded that the Acuris conometric interface does not allow for bacterial translocation under non-dynamic loading conditions.


Assuntos
Coroas/microbiologia , Titânio/farmacologia , Zircônio/farmacologia , Carga Bacteriana , Desenho Assistido por Computador , Humanos , Microscopia Eletrônica de Varredura/métodos , Próteses e Implantes/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...